HP 250C User Manual

Page 141

Advertising
background image

8Ć7

Troubleshooting

C4699Ć90000

LEDs Flashing

Cartridges + Error

: One or more of the cartridges missing or making bad

contact.
D Remove each cartridge. Ensure that the protective tape has been removed,

and look for dirty contacts or wear. Replace each cartridge and run the

BlackĆCartridge Alignment Procedure. (Instructions ' User's Guide,

chapter 1.) D Replace the trailing cable. D Replace the carriage.

D Replace the electronics module.

Paper + Error

: The current plot is too large and does not fit in memory.

D If the plot is araster plot, try sending it with a

no negative motion

RTL

command. D If it is avector plot, try using adriver that performs all the

rasterization of the plot in the host computer before sending it to the plotter.

(See also ' chapter 5, w Memory Usage.) D Otherwise, add more memory by

installing a DRAM SIMM.

Cartridges + Ready:

The plotter is testing and servicing the cartridges.

Wait.

Ready

: The plotter is busy with atask or is receiving afile.

Wait.

Flashing 9

Flashing 13

Flashing 23

Flashing 29

Load Media

: The plotter has a file in memory, which it is waiting to plot, but

no sheet is loaded.
Load a sheet.

Flashing 6