C4699Ć90000

Uneven Fill Density

Symptoms
Blotchy area fills. (PrintĆQuality Plot ' page 8Ć56

1. - Area Fills

.) (See also ' User's Guide,

chapter 4.)

Product Fault

D An incorrect mediaĆtype setting has been selected on the front panel and does not

correspond to the media being used.

Media Fault
The ink is incompatible with the media and does not spread uniformly through the area fill.

Solutions
One or both of the following actions may be appropriate to solve an unevenĆfillĆdensity

problem:

D Change the mediaĆtype setting on the front panel.
D Use a more suitable media type.
D If the problem is occurring in black area fills on color plots printed in

Normal

printĆquality mode, then use

Best

printĆquality mode instead.

Lightfastness

Drawings plotted with the color cartridges 51650C, 51650M, and 51650Y fade when exposed

to light. Colors become less vivid and less bright, and change over time:

D Under direct sunlight: After between 3 and 10 hours.
D Under office light: After about 20 days.
D Laminated and under office light: After about 24 days.

The use of some nonĆHP media types improves the lightfastness.
Strict lightfastness is NOT necessary for the large majority of HP DesignJet 250C customers,

but it will become important in the future for the largeĆformat printing (LFP) market. HP is

working on the development of a new set of inks.

Spray

Symptoms
Smaller dots of sprayed ink located around the point at which the required dot is placed.

Product Fault
The cartridges are positioned too far from the media.

Solution
Adjust the nozzleĆtoĆmedia distance. (Details ' chapter 7.)

Advertising