HP 250C User Manual

Page 72

Advertising
background image

330

350C

6Ć14

Removal and Replacement

C4699Ć90000

8 Pull the electronics module to the right,

in order to easily access the connectors.

9 Disconnect all cables from the visible part

of the main PCA.

C

A

B

Reassembling: The connectors and

cables correspond as follows:
Connector Cable

Clip

FP

Front Panel

A

PINCH

PinchĆArm Sensor

A

COVER

TopĆCover Sensor

A

MEDIA

Media Sensor

B

P1

Trailing Cable

ENC X

Media Motor Encoder

MOT X

Media Motor

C

MOT YCarriage Motor

C

Prevent tugging on the cables at the point

of connection by leaving slack between the

connectors and the clips.

10 Pull the electronics module further to the

right and out of the plotter.

Reassembling: Slide the module into the

plotter until it is stopped by its location

hook on the floor of the plotter. Be careful

not to damage the parallelĆport clamps.

11 If you are changing the electronics module

for a new one, remove the DRAM SIMM(if

installed) from the old module and install

it into the new one. Refer to Chapter 9

before installing the ROM SIMM from the

old module into the new module.

Calibrations: After having installed a new

electronics module, perform the following

calibrations. (Details ' chapter 7.)
1. Black Cartridge Alignment

2. Color Cartridge Test

3. Accuracy Calibration
Note also that the factory spittoon value on the

EEROM of the new electronics module is reset

to 0% used. Keep in mind that the value printed

on the service configuration plot may greatly

underestimate the amount of ink in the spittoon.

Future PCĆbased plotter diagnostics will enable

you to download information from the old

EEROM and upload it to the new EEROM.

Reassembling: After reinstalling the

electronics module, the plotter must be

configured with the correct model ID.