Mediaćaxis test – HP 250C User Manual

Page 178

Advertising
background image

8Ć44 Troubleshooting

C4699Ć90000

MediaĆAxis Test

This tests the operation of the mediaĆaxis motor, encoder and gears.

1 In service mode 1, press

Media-Axis Test

.

The drive roller rotates in steps, each equivalent to one swath advance.

Status. The

Film

LED turns on (steady) if the mediaĆaxis test has not found an error.

If the test fails, the

Film

LED flashes.

OK

Failed

Output to the Serial Port (Viewing Output

'

8-36)

Maximum PWM:

The maximum PWM for each cycle.
A typical media-axis PWM is 52. The maximum allowed is 65.

2 The test continuously repeats itself until you

press the

Shift

key.

Media-Axis

Test

Shift

Advertising