Choosing a suitable plotter environment – HP 250C User Manual

Page 21

Advertising
background image

2Ć3

Site Planning and Requirements

C4699Ć90000

Choosing a Suitable Plotter Environment

(Instructions ' User's Guide, chapter 1, w Position the plotter.)

Environmental Specifications

Hardware:

Environmental Class B2

Operating environment:

Plotter

With cartridges and media:

Temperature

Relative Humidity

0 to 55

_

C (32 to 131

_

F)

5-25%

15 to 35

_

C (59 to 95

_

F)

20-80%

Storage environment:

Plotter/media

Cartridges

Temperature

Relative Humidity

–40 to +70

_

C

(–40 to +158

_

F)

5-95%

–40 to +40

_

C

(–40 to +104

_

F)

Acoustics:*

Operating

D/A1-size plotters
E/A0-size plotters

Idle

Sound Pressure

Sound Power

43 dB (Acoustic)

6.0 bels (A)

45 dB (A)

< 20 dB (A)

< 3.6 bels (A)

*

These specifications are typicalsound pressures at a oneĆmeter bystander position. Idle specification

assumes fan is off.

Plotter Dimensions and Weight

Plotter Model:

D/A1-size plotters

E/A0-size plotters

Length
Depth
Height (window closed)

Weight

1028 mm (40.5 in)

1327 mm (52.2 in)

237 mm (9.3 in)

237 mm (9.3 in)

327 mm (12.9 in)

327 mm (12.9 in)

26 kg (57.2 lb)

31 kg (68.2 lb)