8Ć28 Troubleshooting

C4699Ć90000

EEROM Model ID Configuration Procedure for the DesignJet 330

and 350C

The EEROM model ID configuration procedure only needs to be carried out if:

D A preĆconfigured board is being reused.
D The current board is incorrectly configured to the wrong model ID.
D The plotter shows an unconfigured model ID system error (Steady 135).

It is very rare that these situations will ever occur.

Configure the plotter model ID as follows:

1 Remove the left cover ' page 6Ć10.
2 Disconnect the media motor encoder cable from the main PCA (connector ENC X).
3 Turn the plotter ON in Service Mode 1.
4 Hold the ALT key down and press the Deconfiguration Mode key.

5 Once in Deconfiguration Mode, the first and second LED

columns should light up.

6 Using a suitable tool, shortĆcircuit pins 1 and 2 (the first two

pins on the right) of the media motor encoder connector (ENC X).

The second and third LED columns should light up as you

shortĆciruit the two pins.

7 Once you have shortĆcircuited the two pins, the first and

second LED columns should light up again.

8 Press the

Shift

key to exit the Deconfiguration Mode.

Deconfiguration

Mode

ALT

Shift