Powerćon – HP 250C User Manual

Page 136

Advertising
background image

330

350C

330

350C

8Ć2 Troubleshooting

C4699Ć90000

PowerĆOn

The plotters automatically perform a series ofinternal selftests and mechanical initialization

sequences whenever the user switches the plotter on. These are completed after about 30

seconds. If a failure occurs, an error is indicated on the frontĆpanel LEDs. You can perform a

failure analysis by interpreting the LED error code. (Details ' later in this chapter.)

Self Test and Initialization

The powerĆon selftest and initialization procedure does the following:

1 Initializes the servo processor.
2 Initializes the main processor.
3 Tests communication between the main processor and the servo processor.
4 Tests the EEROM checksum.
5 Tests the servoĆprocessor transfer buffer and interrupt tracking.
6 Tests the ROM checksum.
7 Causes the main processor to initialize certain firmware modules.
8 Performs a subset of the electrical service test.
9 Checks the cover sensor.

If the cover is open, nothing further happens until you close it.

10 Initializes the carriage axis (YĆaxis).

11 Uses the mark encoder to check the start ofthe drive roller.

12 Ejects any loaded sheet.

Does not eject roll media if loaded.

13 Checks the media sensor.
14 Sets the plotter to accept media.