HP 250C User Manual

Page 158

Advertising
background image

8Ć24 Troubleshooting

C4699Ć90000

Filename

Failure

(andmost frequent causes)

Line Number

Filename

Failure

(andmost frequent causes)

Firmware

A.01.00

testmode.c

3684

Error in DRAM data test:

D Faulty carriage.

testmode.c

3691

Error in DRAM addresses test:

D Faulty electronics module.

testmode.c

3698

Unknown DRAM error:

D Faulty electronics module.

testmode.c

3722

Error in the test of the inĆbuilt ROM and

ROM SIMM performedat powerĆon:

D ROM SIMM badly seated.
D Faulty ROM SIMM.
D Faulty electronics module.

testmode.c

3733

Error in the test of the maskedROM:

D Faulty electronics module.

main.c

238

Failure in cartridge initialization:

D Faulty or badly connected trailing cable.

main.c

381

Failure in fan connection test:

D Faulty electronics module.

main.c

230 or

354

Model ID configuration incorrect.

Reconfigure the plotter ' page 8Ć28.

selftest.c

1502

Failure in test to actuate inĆbuilt ROM or

ROM SIMM:

D ROM SIMM badly seated.
D Faulty ROM SIMM.
D Faulty electronics module.

selftest.c

1506

Failure in maskedĆROM test:

D Faulty electronics module.

selftest.c

1513

Failure in mainĆPCA DRAM test:

D Faulty electronics module.

Advertising