6Ć30

Removal and Replacement

C4699Ć90000

7 Remove the engaging lever.

8 Remove the spring from the bailĆgear

assembly.

9 Loosen the screw from the top of the

bailĆgear assembly.

Torx-8

10 Remove the screw from the plastic bail

gear.
You may need to hold the bail cam steady

inside the sideĆplate at the same time. You

can access the cam through the hole

underneath the sideĆplate.

Torx-15

11 Pull the bail gear assemblyout from the

plotter.
The cam falls to the floor of the plotter.