HP 250C User Manual

Page 146

Advertising
background image

Paper + Error + Fast + Load Media:

Error in XĆaxis encoder quadrature

(media-axis). Possible causes are:
D Incorrect routing of the motor cables.

D Electrical noise in motors. D Faulty motor encoder. D Motor received an

electrostatic discharge while operating.

Paper + Cartridges + Error + Film + Fast:

CartridgeĆalignment firmware error.

Try one or more of the following:
D Turn the plotter off, and then on again to see if the problem disappears.

D Ensure that the cartridges are correctly seated. D Replace cartridges.

D If the problem remains, consult recent service notes for a possible solution.

D If no service note deals with this error, report the problem to your HP

Response Center. Note conditions and actions before error occurred. Include

setup sheet and service configuration plot in report.

Paper + Error + Film + Fast + Load Media:

Error in bailĆlift mechanism. The

bailĆlift system is unable to raise or lower the bail. (It is the carriage that

tests to see whether the bail is in the correct position by trying to knock

against it.)
D Check the bailĆlift system to see if it is working correctly. D Use the bail

cycle test to help troubleshoot.

For more precise troubleshooting ' page 8Ć19, w System Errors.

Error + Film + Fast + Load Media:

Error in encoderĆstrip quadrature (carriage

axis). Possible causes are:
D Incorrect routing of the motor cables.

D Trailing cable is faulty or badly connected. D Faulty carriage.

D Motor received an electrostatic discharge while operating.

Steady 1356

Steady 12345

Steady 13456

Steady 3456

Paper + Error + Fast + Special:

Contents of the EEROM have been lost.

D Perform the electrical test. If it fails, the main PCA is faulty.

D Don't rule out the fact that any new service test that you perform may

corrupt the EEROM.

For more information ' page 8Ć27, w EEROM Errors.

Steady 1357

Paper + Error + Film + Ready:

Failure of centronics READ.

Firmware error or faulty electronics module.

Steady 1349

8Ć12 Troubleshooting

C4699Ć90000

Advertising