7Ć14 Calibrations and Adjustments

C4699Ć90000

3 Tighten or loosen the indicated screw on the carriage. This will adjust the carriage angle

on the slider rod, thus increasing or decreasing the carriageĆtoĆmedia distance.

ОО

ОО

Gap
Increases

Rotating
Clockwise

О

О

Torx-8

4 Check the carriageĆtoĆmedia distance ' page 7Ć11.
5 Reinstall the top of the carriage.
6 Check the trailing cable to make sure that it is positioned under the plastic tabs at the

back of the carriage cover, and not above them.

Trailing cable
under tabs !

Otherwise, the plotter will not be able to load media.