Fuji Bikes FRENIC 5000G11S/P11S User Manual

Page 105

Advertising
background image

8-2

Terminal block

Is there damage?

Visual inspection

Not abnormal

Main circuit

Smoothing
capacitor

1) Is there electrolyte leakage, discoloration,

crazing, or swelling of the case?

2) Is the safety valve not protruding or are

valves protruding too far?

3) Measure the capacitance if necessary.

1), 2) Visual inspection
3) * Estimate life

expectancy from
maintenance
information and from
measurements using
capacitance
measuring
equipment.

1), 2) Not abnormal
3) Capacitance ≧

initial value x 0.85

Resistor

1) Is there unusual odor or damage to the

insulation by overheating?

2) Is there an open circuit?

1) Visual and

olfactory inspection

2) Conduct a visual

Inspection or use
a multimeter by
removing the
connection on one
side.

1) Not abnormal
2) Less than about

±10% of the
indicated
resistance value

Transformer
and reactor

Is there abnormal buzzing or an unpleasant
smell?

Aural, olfactory, and
visual inspection

Not abnormal

Main circuit

Magnetic
conductor and
relay

1) Is there rattling during operation?
2) Are the contacts rough?

1) Aural inspection
2) Visual inspection

1),2)Not abnormal

Control circuit

Control PC
board and
connector

1) Are there any loose screws or connectors?
2) Is there an unusual odor or discoloration?
3) Are there cracks, damage, deformation, or

excessive rust?

4) Is there electrolyte leakage or damage to

the capacitor?

1) Tighten.
2) Visual and olfactory

inspection

3) Visual inspection
4) * Estimate life

expectancy by visual
inspection and
maintenance
information

1),2),3),4)Not

abnormal

Cooling fan

1) Is there abnormal sound or vibration?
2) Are nuts or bolts loose?
3) Is there discoloration due to overheating?

1) Aural and visual

inspection. Turn
manually (confirm the
power is off).

2) Tighten.
3) Visual inspection
4) * Estimate life

expectancy by
maintenance
information

1) The fan must

rotate smoothly.

2), 3) Not abnormal

Cooling system

Ventilation

Is there foreign matter on the heat sink or intake
and exhaust ports?

Visual inspection

Not abnormal

Note: If equipment is stained, wipe with a clean cloth. Vacuum the dust.

∗Estimation of life expectancy based on maintenance information

The maintenance information is stored in the inverter keypad panel and indicates the

electrostatic capacitance of the main circuit capacitors and the life expectancy of the electrolytic
capacitors on the control PC board and of the cooling fans. Use this data as the basis to
estimate the life expectancy of parts.
1) Determination of the capacitance of the main circuit capacitors

This inverter is equipped with a function to automatically indicate the capacitance of the
capacitors installed in the main circuit when powering up the inverter again after disconnecting
the power according to the prescribed conditions.
The initial capacitance values are set in the inverter when shipped from the factory, and the
decrease ratio (%) to those values can be displayed.
Use this function as follows:

Advertising