4-14


Inverter type of data
stored in the keypad
panel

60.00

60.00

1.DATA SETTING
2.DATA CHECK
3.OPR MNTR
4.I/O CHECK

5.MAINTENANC
6.LOAD FCTR
7.ALM INF
8.ALM CAUSE
⇒9.DATA COPY

Error processing

Data check

(verify)

<DATA COPY>

040HP-4
READ

<DATA COPY>

040HP-4
VERIFY

Mode (data check)

<DATA COPY>

040HP-4
VERIFY

„„„„

Data check in progress

<DATA COPY>

040HP-4
WRITE

INV RUNNING

RUN

PRG

⇒PRG

MENU
F/D

⇒LED SHIFT

<DATA COPY>

040HP-4
VERIFY
COMPLETE

„„„„„„„„„„„„„„„

Data check complete

<DATA COPY>

040HP-4
WRITE

1) Change disabled during operation

If a write operation is attempted during an inverter
operation, or vice versa, the error message below will
appear.
After stopping the inverter and pressing , retry the
write operation.

2) Memory error

If a write operation is attempted while data has not been
saved (i.e., no data) in the keypad panel data memory
during the read mode, the following error message will
appear:

<DATA COPY>


WRITE

MEMORY ERROR

3) Verify error

During a data check (verify) operation, if data stored in
the keypad panel differs from data stored in the inverter,
the following error message is displayed to indicate the
function No. The data check is suspended.
To continue the data check and check for other
mismatching data, press . To stop the data check
and switch to another operation, press .

<DATA COPY>

075HP-4
WRITE

ERR:F25

„„„„

4) Data protection

When WRITE to the inverter which is protected by
"Data protection" function, the following error message
will appear. After released the protection, write
operation is attempted.

<DATA COPY>

040HP-4
WRITE

DATA PRTCTD

FUNC
DATA

FUNC
DATA

FUNC
DATA

RESET