Fuji Bikes FRENIC 5000G11S/P11S User Manual

Page 122

Advertising
background image

9-13

Data format [13]

Pattern operation

15

14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Direction

of rotation

0

Time

Index portion

Data portion

0: 1st ACC/DEC time

0: 0.01 X

001

–999 (0.00–9.99)

0: FWD

1: 2nd ACC/DEC time

1: 0.1

X

100

–999 (10.0–99.9)

1: REV

2: 3rd ACC/DEC time

2: 1

X

100

–999 (100–999)

3: 4th ACC/DEC time

3: 10

X

100

–999 (1000–9990)

Example) If C22 (Stage1) = 10.0s R2 (10s, reverse rotation, acceleration time 2/deceleration time 2)
Since 10.0 = 0.1 X 100 > 9000

H

+ 0400

H

+ 0064

H

= 9464

H



Data format [14]

Operation command

15

14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

RST 0 0 0 0 X9 X8 X7 X6 X5 X4 X3 X2 X1 REV

FWD

(All bit are ON by 1)
Example If S06 (operation command) = FWD, X1 and X5 = ON

0000 0000 0100 0101

b

= 0045

H



Data format [15]

Universal output terminal

15

14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

0 0 0 0 0 0 0 0 0 0 0 Y5

Y4

Y3

Y2

Y1

(All bit are ON by 1)
Example) If M15 (Universal output terminal)=Y1 and Y5 = ON

0000 0000 0001 0001

b

= 0011

H



Data format [16]

Operating state

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

BUSY WR RL

ALM

DEC

ACC

IL

VL

TL

NUV

BRK

INT

EXT

REV

FWD

(All bit are ON or active by 1)

FWD: Forward operation

IL:

Current limiting

REV: Reverse operation

ACC: Under acceleration

EXT: DC braking active (or pre-excitation)

DEC: Under deceleration

ALM:

Inverter

fault

INT: No Output

RL:

Transmission valid

BRK: Braking active

WR:

Function writing privilege

NUV: DC link voltage is established

0: Keypad panel

(undervoltage at 0)

1: RS-485

TL:

Torque limiting

2: Fieldbus (option)

VL:

Voltage limiting

BUSY: Processing data write

Advertising