E:Extension Terminal Functions

Factory setting

Func

No.

NAME

LCD Display

Setting range

Unit

Min.

Unit

-30HP 40HP-

Change

during op

User

Set value

Remark


E01 X1 terminal function

E01

X1 FUNC

0 to 35

-

-

0

NA

E02 X2 terminal function

E02

X2 FUNC

1 NA

E03 X3 terminal function

E03

X3 FUNC

2 NA

E04 X4 terminal function

E04

X4 FUNC

3 NA

E05 X5 terminal function

E05

X5 FUNC

4 NA

E06 X6 terminal function

E06

X6 FUNC

5 NA

E07 X7 terminal function

E07

X7 FUNC

6 NA

E08 X8 terminal function

E08

X8 FUNC

7 NA

E09 X9 terminal function

E09

X9 FUNC

8 NA

E10 Acceleration time 2

E10

ACC TIME2

s

0.01

6.00

20.00

A

E11 Deceleration time 2

E11

DEC TIME2

6.00 20.00 A

E12 Acceleration time 3

E12

ACC TIME3

6.00 20.00 A

E13 Deceleration time 3

E13

DEC TIME3

6.00 20.00 A

E14 Acceleration time 4

E14

ACC TIME4

6.00 20.00 A

E15 Deceleration time 4

E15

DEC TIME4

0.01 to 3600s

6.00 20.00 A

E16 Torque limiter 2

(Driving)

E16

DRV TRQ 2

G11S: 20 to 200%, 999

%

1

999

A

P11S: 20 to 150%, 999

E17 (Braking)

E17

BRK TRQ 2

G11S: 0%, 20 to 200%, 999

%

1

999

A

G11S: 0%, 20 to 150%, 999

E20 Y1 terminal function

E20

Y1 FUNC

0 to 37

-

-

0

NA

E21 Y2 terminal function

E21

Y2 FUNC

1 NA

E22 Y3 terminal function

E22

Y3 FUNC

2 NA

E23 Y4 terminal function

E23

Y4 FUNC

7 NA

E24 Y5A, Y5C terminal func.

E24

Y5 FUNC

10 NA

E25 Y5 RY operation mode

E25

Y5RY MODE

0,1

-

1

0

NA

E30 FAR

function

(Hysteresis)

E30

FAR HYSTR

0.0 to 10.0Hz

Hz

0.1

2.5

A

E31 FDT

function

(Level)

E31

FDT1 LEVEL

G11S: 0 to 400Hz

Hz

1

60

A

P11S: 0 to 120Hz

E32 signal

(Hysteresis)

E32

FDT1 HYSTR

0.0 to 30.0Hz

Hz

0.1

1.0

A

E33 OL1 function(Mode select)

E33

OL1 WARNING

0: Thermal calculation

-

-

0

A

1: Output current

E34 signal

(Level)

E34

OL1 LEVEL

G11S: 5 to 200%

A

0.01

Motor rated current

A

P11S: 5 to 150%

E35 (Timer)

E35

OL1 TIMER

0.0 to 60.0s

s

0.1

10.0

A

E36 FDT2

function

(Level)

E36

FDT2 LEVEL

G11S: 0 to 400Hz

Hz

1

60

A

P11S: 0 to 120Hz

E37 OL2

function

(Level)

E37

OL2 LEVEL

G11S: 5 to 200%

A

0.01

Motor rated current

A

G11S: 5 to 150%

E40 Display coefficient A

E40

COEF A

-999.00 to 999.00

-

0.01

0.01

A

E41 Display coefficient B

E41

COEF B

-999.00 to 999.00

-

0.01

0.00

A

E42 LED Display filter

E42

DISPLAY FL

0.0 to 5.0s

s

0.1

0.5

A

E43 LED

Monitor

(Function)

E43

LED MNTR

0 to 12

-

-

0

A

E44

(Display at STOP mode)

E44

LED MNTR2

0, 1

-

-

0

A

E45 LCD

Monitor

(Function)

E45

LCD MNTR

0, 1

- -

0

A

E46

(Language)

E46

LANGUAGE

0 to 5

-

-

1

A

E47

(Contrast)

E47

CONTRAST

0(soft) to 10(hard)

-

-

5

A

C:Control Functions of Frequency

Factory setting

Func

No.

NAME

LCD Display

Setting range

Unit

Min.

Unit

-30HP

40HP-

Change

during op

User

Set value

Remark


C01 Jump frequency

(Jump freq. 1)

C01

JUMP Hz 1

Hz

1

0

A

C02

(Jump freq. 2)

C02

JUMP Hz 2

0 A

C03

(Jump freq. 3)

C03

JUMP Hz 3

G11S: 0 to 400Hz
P11S: 0 to 120Hz

0 A

C04

(Hysteresis)

C04

JUMP HYSTR

0 to 30Hz

Hz

1

3

A

C05 Multistep frequency

(Freq. 1)

C05

MULTI Hz-1

Hz

0.01

0.00

A

C06 setting

(Freq. 2)

C06

MULTI Hz-2

0.00 A

C07

(Freq. 3)

C07

MULTI Hz-3

0.00 A

C08

(Freq. 4)

C08

MULTI Hz-4

0.00 A

C09

(Freq. 5)

C09

MULTI Hz-5

0.00 A

C10

(Freq. 6)

C10

MULTI Hz-6

0.00 A

C11

(Freq. 7)

C11

MULTI Hz-7

0.00 A

C12

(Freq. 8)

C12

MULTI Hz-8

0.00 A

C13

(Freq. 9)

C13

MULTI Hz-9

0.00 A

C14

(Freq. 10)

C14

MULTI Hz-10

0.00 A

C15

(Freq. 11)

C15

MULTI Hz-11

0.00 A

C16

(Freq. 12)

C16

MULTI Hz-12

0.00 A

C17

(Freq. 13)

C17

MULTI Hz-13

0.00 A

C18

(Freq. 14)

C18

MULTI Hz-14

0.00 A

C19

(Freq. 15)

C19

MULTI Hz-15

G11S: 0.00 to 400.00Hz
P11S: 0.00 to 120.00Hz

0.00 A