Zero/span adjustment, 000%cs – Fujimoto Fuji Differential Pressure Transmitter FKK 4 User Manual

Page 24

Advertising
background image

18

INC

A:

CALIBRATE

< INC > < LRV >

1

CL

ENT

2

A-1:

CALIBRATE
LRV

ЧЧЧ

.

ЧЧ

%

CHNG OK? < ENT/CL >

3

A-2:

CALIBRATING

LRV

ЧЧЧ

.

ЧЧ

%

4

A-1:

CALIBRATE

LRV

ЧЧЧ

.

ЧЧ

%

< ENT > < CL >

ENT

ЧЧЧ

.

Ч

kPa

ЧЧЧ

.

Ч

kPa

ЧЧЧ

.

Ч

kPa

5

A-3:

CALIBRATE
URV

ЧЧЧ

.

ЧЧ

%

CHNG OK? < ENT/CL >

6

A-4:

CALIBRATING

URV

ЧЧЧ

.

ЧЧ

%

7

A-3:

CALIBRATE
URV

ЧЧЧ

.

ЧЧ

%

< ENT > < CL >

ЧЧЧ

.

Ч

kPa

ЧЧЧ

.

Ч

kPa

ЧЧЧ

.

Ч

kPa

LRV

CL

CL

ENT

CL

ENT

URV

< URV >

< Zero adjustment >

< Span adjustment >

B : OUTPUT ADJ

Zero/span adjustment

Zero and span are adjustable by apply-
ing an actual pressure.
When pressing <LRV> under display 1
the screen for zero adjustment 2
appears, and that for span adjustment 5
appears when pressing <URV>.
Under display 2 , after applying actual
pressure equal to zero point, press
<ENT> two times. Zero adjustment will
be over.
When adjustment is made at any point
other than zero, input the pressure value
at that point at the display of 2 , then
press the <ENT> key at the display of 3
while applying a corresponding pres-
sure to the transmitter.
Under display 5 , after applying actual
pressure equal to desired span, press
<ENT> two times. Span adjustment
will be over.
When adjustment is made at any point
other than span, input the pressure value
at that point at the display of 5 , then
press the <ENT> key at the display of 6
while applying a corresponding pres-
sure to the transmitter.

Press LRV or URV at display of 1 .
When the following is displayed, it means that calibration can not be made because
Menu No. H: LINEARIZE is effective. In this case, set INVALID on the panel of
No. H: LINEARIZE.

1. Span adjustment should be performed after zero adjustment is completed.
2. When the actual input exceeds the adjustable range, [NOT CALB <CL>] is

displayed.
In this case, adjustment is required again.

Adjustable range

Zero adjustment: Within

±40% of maximum span

Span adjustment: Within

±20% of calibrated span

3. When the adjustment point does not meet the following condition,

[SETTING ERR<CL>] is displayed. In this case, adjustment is required again.

Adjustment point setting condition

–1.000%CS

(*)

PL 100.000%CS

(*)

0.000%CS

(*)

PH 110.000%CS

(*)

A-1:CALIBRATE
Can’t proceed.
Set Linearize
invalid

<CL>

(*) : CS (Calibrated Span) is equal to measuring range.

Important

PL =

(Lower adjustment point) - LRV

URV - LRV

× 100

PH =

(Higher adjustment point) - LRV

URV - LRV

Ч 100

Advertising