Gas measurement

Liquid measurement

Steam measurement

Upper

Upper

Lower

Within 45° upward from
vertical direction

Within 45° downward
from horizontal direction

Within 45° upward from
horizontal direction

45°

45°

45

°

45°

45°

Lower

45°

Main process piping

Pressure source

Pressure source is

located upper side of

main process piping

Pressure source is

located lower side of

main process piping

Pressure source is

located upper side of

main process piping

6.2.2

Piping of pressure transmitter type : FKP

Removal of protective cap
The process connection port of the transmitter is fitted with a protective cap. Before piping,
remove the cap carefully. When removing the cap, carefully protect the threaded portion and
sealing face from damage.

Connection of transmitter and impulse pipe

• Impulse pipe should directly be screwed into the transmitter.

• After connection, close the stop valve of transmitter in order to prevent foreign materials

from entering the inside.

Position of process taps (Horizontal main process piping)
The position of the process tap is determined by the relationship between condition, charac-
teristics and measurement point of process fluid. Note the following figures when planning
and installing the piping.