Con nector Info rmat ion
Logic Cables and Connectors

3–18

MMDS0508 Target Interface

3.4 Logic Cables and Connectors

The diagram below shows the pin numbering for both pod A and pod B logic cable
connectors.

Table 3.2

lists the pin assignments.

Table 3.1

. Serial Connector and Cable Pin Assignments

Connector Pin

Mnemonic

Signal

1

DCD

DATA CARRIER DETECT — Output signal that
indicates detection of an acceptable carrier
signal.

2

RX

RECEIVE DATA — Serial data output line.

3

TX

TRANSMIT DATA — Serial data input line.

4

DTR

DATA TERMINAL READY — Input signal that
indicates on-line/in-line/active status.

5

GND

GROUND

6

DSR

DATA SET READY — Output signal that
indicates on-line/in-line service/active status.

7

RTS

REQUEST TO SEND — Input signal that
requests permission to transfer data.

8

CTS

CLEAR TO SEND — Output signal that indicates
a ready-to-transfer data status.

19

1

20

2