Freescale Semiconductor Target Interface MMDS0508 User Manual

Page 75

Advertising
background image

App en dix

MMDS Commands

A–75

MMDS0508 Target Interface

A.1.3.27 Description

The SQ command sets the analyzer sequencer mode. If this command includes no
parameter values, the command interpreter opens the Bus Analyzer Configuration
dialog box: select the Sequencer Setup dialog box to program the sequencer
interactively. Selecting from the Setup menu is another way to open the Sequencer
Setup dialog box.

Example:

SQ ALL 100

Specifies 100 bus cycles. After 100 cycles, the analyzer disarms itself and stops
recording.

Example:

SQ EVENT 10 ;S

Specifies recording 10 event cycles, then stopping the emulator.

TT

A.1.3.28 Short Description

display time tag difference.

A.1.3.29 Syntax

TT [sframe [eframe]]

sframe

: The starting frame number.

eframe

: The ending frame number; without this value, the system uses the end frame

in the trace buffer to calculate the difference.

A.1.3.30 Description

The TT command displays the difference between the time tags in the two trace frames
of the analyzer display. Without frame-number values, this command displays the
difference between the beginning and ending frames

Example:

Freescale Semiconductor, Inc.

For More Information: www.freescale.com