MMDS Target Comp onent

4.8 MMDS0508 Menu Entries

4–35

MMDS0508 Target Interface

Figure 4.14

Target Signals

This dialog box lets you specify the MCU clock and the reset signal connection.
Warning: in order to use any of these clock signals, you must configure EM jumper
headers correctly.

This dialog box displays settings that the system reads from the MMDS0508. Click Ok
to close the dialog box, and to write values back to the MMDS0508. Check the Save
and Reload
checkbox to have the system save the configuration, then reload this
configuration the next time you start the debugger.

4.8.4.1 MCU Clock

The MCU Clock area lets you specify a different MCU clock, provided that the EM
configuration is correct.

4.8.4.2 Reset

The Reset area lets you specify the reset-signal connection with the target system.

4.8.5 Bus Tracing

To run the Bus Analyser, choose the MMDS0508>Bus Trace menu selection. Please
see the Bus Analyser section of this document for details.