App en dix
MMDS Commands

A–62

MMDS0508 Target Interface

address range

: A range of addresses to trip the trigger. To specify a range, use

starting and ending constants, or use a starting address and a length value:

start-address

[:

mask

][..

end-address

]

or

start-address

[:

mask

][,

length

]

If you include a mask value, the system comparison involves only the address bits that
correspond to ones (1s) of the mask. If you include a length and a mask, the system
adds the length to the start address, then applies the mask to the start address and to the
sum, to obtain the end address.

,

: The comma directs the analyzer to not include an address, address range, data, data

range, or clip value in the trigger definition.

data

:

Data value that is to trip the trigger:

value[:mask]

If you include a mask value, the system comparison involves only the value bits that
correspond to ones (1s) of the mask.

data-range:

A range of data values to trip the trigger. To specify a range, use start and end values,
or use a starting value and a length:

start-value

[

:

mask

][

..

end-value

]

or

start-value

[

:

mask

][

::

length

]

If you include a mask value, the system comparison involves only the value bits that
correspond to ones (1s) of the mask. If you include a length and a mask, the system
adds the length to the start value, then applies the mask to the start value and to the
sum, to obtain the end address.

clips

A 15-bit value that defines MMDS0508 analyzer logic clip signals for the trigger,
specified as:

clips

[

:

mask

]

If you include a mask, the system comparison involves only the value bits that
correspond to ones (1s) of the mask. For example, the code 0x1F:0x1F, sets all clips

Freescale Semiconductor, Inc.

For More Information: www.freescale.com