MMDS Target Componen t
4.10 Bus Analyzer

4–48

MMDS0508 Target Interface

The analyzer can display its contents as text or as a graphic. You can have a textual
display of all frames, or a textual display of only instruction-start frames. Additionally,
you can choose the Trace>Items... menu selection to specify items for display.

4.10.4.3 Textual Display

If you choose the Textual format, the software displays all the frames of the trace
buffer contents, in a textual form, as shown in

Figure 4.20

. Use the vertical scroll bar

to scroll to other frames. Use the horizontal scroll bar to scroll to other signals.

Each display line gives the data of one frame: text below explains these data items.
You can add or remove data items. (Please see the section Adding / Removing Items in
the Trace Window
.) The marker consists of two horizontal lines, which facilitate
reading the data items for a specific frame; the analyzer highlights the number of the
marked frame.

Figure 4.20

Trace Textual Format Display

Frame This column lists the cycle (or frame) number of each frame: identifying
integers, from 1 to 8191. The most recently stored frame has number 8191 (or the
highest number all the frames stored).

4.10.4.3.1 Events

This column lists identifiers of matching events. That is, if frame data matches any
event data definitions, the analyzer displays the event identifiers (A, B, C, or D) in this
column.

Freescale Semiconductor, Inc.

For More Information: www.freescale.com