list

: A list of trigger identifiers (A, B, C, or D), separated by comma or space

characters.

*

: All triggers.

A.1.2.9 Description

The TD command disables specified triggers. Use the Set Trigger (ST) command to set
triggers; use the Trigger Enable (TE) command to enable triggers. Use the Clear
Triggers (CT) command to clear triggers.

Example:

TD A B

Disables triggers A and B.

Example:

TD *

Disables all triggers.

TE

A.1.2.10 Short Description

trigger enable.

A.1.2.11 Syntax

TE list | *

list

: A list of trigger identifiers (A, B, C, or D), separated by comma or space

characters.

*

: All triggers.

A.1.2.12 Description

The TE command enables specified triggers. Use the Set Trigger (ST) command to set
triggers; use the Trigger Disable (TD) command to disable triggers. Use the Clear
Triggers (CT) command to clear triggers.

Example: