Freescale Semiconductor Target Interface MMDS0508 User Manual
Page 65

App en dix
MMDS Commands
A–65
MMDS0508 Target Interface
list
: A list of trigger identifiers (A, B, C, or D), separated by comma or space
characters.
*
: All triggers.
A.1.2.9 Description
The TD command disables specified triggers. Use the Set Trigger (ST) command to set
triggers; use the Trigger Enable (TE) command to enable triggers. Use the Clear
Triggers (CT) command to clear triggers.
Example:
TD A B
Disables triggers A and B.
Example:
TD *
Disables all triggers.
TE
A.1.2.10 Short Description
trigger enable.
A.1.2.11 Syntax
TE list | *
list
: A list of trigger identifiers (A, B, C, or D), separated by comma or space
characters.
*
: All triggers.
A.1.2.12 Description
The TE command enables specified triggers. Use the Set Trigger (ST) command to set
triggers; use the Trigger Disable (TD) command to disable triggers. Use the Clear
Triggers (CT) command to clear triggers.
Example:
Freescale Semiconductor, Inc.
For More Information: www.freescale.com