App en dix

MMDS Commands

A–63

MMDS0508 Target Interface

of Term A to H. Without a mask, the ST command uses the unmasked value 0x1F for
the clips.

Each trigger clip line has three options:

H - High

L - Low

X - Don’t Care

The bits of the clips and mask words are:

Bit: Signal:

0 Group A- BRN

1 RED

2 ORG

3 YEL

4 GRN

6 LIR (active low)

;R

:

Trigger on a read bus cycle only.

;W

:

Trigger on a write bus cycle only.

;RW

:

Trigger on a read or write bus cycle.

;D

:

Disable trigger (set trigger value, but disable trigger).

LIR

:

Trigger on a specific value for LIR signal.

LIR=H triggers when LIR is high.

LIR=L triggers when LIR is low.

LIR=X triggers when LIR is high or low.

If either the address or the data value of this command is a range, the analyzer
interprets both values as ranges. For example, the analyzer interprets the command
STC 8 20..40

as STC 8.. 8 20..40; it interprets the command STC 8..9

20

as STC 8..9 20..20.

If the command lacks any R, W, or RW value, the trigger defaults to read/write.

You can set the LIR signal with the clips (bit 6) or the LIR option.

Freescale Semiconductor, Inc.

For More Information: www.freescale.com