Freescale Semiconductor Target Interface MMDS0508 User Manual

Page 74

Advertising
background image

App en dix
MMDS Commands

A–74

MMDS0508 Target Interface

would trip the trigger: 0xC000, 0xC001, 0xC002, or 0xC003. For
Address 0x00B0, Mask 0xFFF0, any address in the range
0x00B0..0x00BF would trip the trigger.

SQ

A.1.3.25 Short Description

set sequencer.

A.1.3.26 Syntax

SQ [mode [count] [;S] ]

mode

: One of these values:

ALL

(records all bus cycles)

EVENT

(records only events)

SEQ0

(sequential A+B+C+D)

SEQ1

(sequential A+B->C+D)

SEQ2

(sequential A->B->C D<-)

SEQ3

(sequential A->B->C->D)

SEQ4

(nth event after A+B+C+D)

count

: Terminal count for the ALL and EVENT modes (a decimal value). Directs

recording of count frames (of the appropriate type). When the number of frames
recorded reaches the count value, the analyzer stops recording and is disarmed. If this
command has no count value, the analyzer records continuously whenever the
emulator is running. For sequential modes, the count value is the decimal post-trigger
count, directing recording of count bus cycles after the trigger point. The default count
value is 1. If no count value follows the mode value ALL, the system records frames
for all cycles. If no count value follows the mode value EVENT, the system records all
the events.

;S

: Specifies stopping the emulator when recording stops, letting you use the analyzer

as a sequenced breakpoint machine.

Freescale Semiconductor, Inc.

For More Information: www.freescale.com

Advertising