Freescale Semiconductor Target Interface MMDS0508 User Manual

Page 71

Advertising
background image

App en dix

MMDS Commands

A–71

MMDS0508 Target Interface

500,000 Hz divided by an integer. Thus, 50000 is valid, but 49000 is not. (If you
specify 49000, the system rounds the value up the the next higher valid frequency:
50000.)

A.1.3.21 Description

The SC command sets the source for the time tag clock, which increments the trace
buffer time tag. If this command includes no parameter values, the command
interpreter opens the Bus Analyzer Configuration dialog box. You can use the Time
Tag Clock page to reach the Clock Specification dialog box, then set the clock sources
interactively.

Example:

SC PROGRAM 100

Sets the programmable clock, running at 100Hz, as the time clock source.

Example:

SC OSC8MHZ

Sets the 8 Mhz oscillator as the time tag clock source.

SP

A.1.3.22 Short Description

set analyzer search pattern.

A.1.3.23 Description

The SP command defines a search pattern for the bus analyzer trace buffer. The go to
pattern (GP) command starts the search for the pattern defined by the most recent SP
command. If the SP command includes no parameter values, the command interpreter
opens the Bus Analyzer Configuration dialog box. You can use the Pattern page to
define the pattern interactively.

A.1.3.24 Syntax

SP [!] [(<address> | ,) [(<data> | ,) [(<clips> | ,)[LIR =
(X
| L | H)]]]][;R | ;W| ;RW]

Freescale Semiconductor, Inc.

For More Information: www.freescale.com