DANGER

This appliance is equipped with a special (grounding) plug for your protection
against electrical shock, and must be plugged directly into a properly grounded re-
ceptacle. Do not cut, remove, or otherwise bypass the grounding prong on this
plug!

DANGER

This appliance requires electrical power for operation. Place the gas control valve in
the OFF position in case of a prolonged power outage. Do not attempt to operate
this appliance during a power outage.

WARNING

To ensure the safe and efficient operation of the fryer and hood, the electrical plug
for the 120-volt line, which powers the hood, must be fully engaged and locked in its
pin and sleeve socket.

2.1.4 Australian

Requirements

To be installed in accordance with AS 5601, local authority, gas, electricity, and any other relevant statutory
regulations.

If casters are fitted, the installation must comply with AS5601 and AS1869 requirements.

2.2 Caster

Installation

On an appliance with casters; the installation shall be made with a connector that complies with the Standard for
Moveable Gas Appliances, ANSI Z21.69 • CSA 6.16, and a quick disconnect device that complies with the
Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 • CSA 6.9.

2.3 Pre-Connection

Preparations

DANGER

DO NOT connect this appliance to the gas supply before completing each step in
this section.

After the fryer has been positioned under the exhaust hood, ensure the following has been accomplished:

1. Adequate means must be provided to limit the movement of fryers without depending upon the gas line

connector and the quick-disconnect device or its associated piping to limit the appliance movement. If a
flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. The
restraining cable and installation instructions are packed with the flexible hose in the accessories box that was
shipped with your unit.

DANGER

The appliance area must be kept free and clear of combustible material at all times.

2. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the hood be 24 in.

(600 mm) when the appliance consumes more than 120,000 BTU per hour.