12 programming level one, 5 pan to waste – Frymaster BIGLA30 User Manual

Page 47

Advertising
background image

4-23

4.11.5 Pan to Waste

Pan to waste selection is an option that allows bulk oil systems to pump excess oil in the pan to the
bulk oil waste tanks without draining the existing oil in the frypot.

1. With the computer

OFF, press and hold the filter button for the vat to be

refilled for three seconds.

The computer displays

filter menu for three seconds, changing to MAINT Filter.

2. Use the

t and

ubuttons to scroll to PAN TO WASTE.

3. With

PAN TO WASTE displayed, press the (1 yes) button to

continue.

The computer displays

PAN TO WASTE? alternating with yes no.

4. Press the

(yes) button and go to Section 4.10.4..3 page 4-18 and

continue after step 6 or press (2

NO) button to exit to filter menu.



4.12 Programming Level One

Level one programming is used to enter new products, control when AIF (auto intermittent filtration)
is disabled and perform deep clean (boil-out) and high-limit test.

To enter Level 1 programming mode:

1. With the computer

OFF, press the TEMP and INFO buttons

simultaneously for THREE seconds until

LEVEL 1 is displayed; a chirp

sounds.


The computer displays

ENTER Code.

2. Enter 1234.

1

2

3

4

(1234)

The computer displays

level 1 program for three seconds changing to Product

selection.

Advertising