3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent on the

blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel and housing with
hot tap water, then dry with a clean cloth. (See Figure 3)

Blower Housing

Blower Wheel

Wrap the motor and wires

with plastic wrap or a

plastic bag.

Figure 3

4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly and

blower housing. Reinstall the blower assembly in the fryer.

5. Reinstall the blower shield or shield assembly.

6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.2.

7. After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports

located on each side of the combustion air blower. (See Figure 4)

Figure 4

The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable
table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is observed, or if there are dark
spots on a burner face, the air/gas mixture requires adjustment.

On the side of the blower housing opposite the motor is a plate with one or two locking nuts (see illustration on the
following page). Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to
open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position