13 programming level two – Frymaster BIGLA30 User Manual

Page 53

Advertising
background image

4-29

The vat begins to heat. The computer displays the actual vat temperature during the test. When the
temperature reaches 410°F ± 10° F (210°C ± 12°C)*, the computer displays

hot hi-1 alternating

with the actual temperature (ex.

410F) and continues heating.

*NOTE: In computers used in the European Union (those with the CE mark), the temperature is
395°F (202°C).

The fryer continues heating until the second high limit trips. Generally this happens once the
temperature reaches 423°F to 447°F (217°C to 231°C) for non-CE high limits and 405°F to 426°F
(207°C to 219°C) for CE high limits.

Once the high-limit opens the computer displays

HELP HI-2 alternating with the actual

temperature (ex.

430F).

5. Release the (1

yes) button.

If the high-limit fails, the computer displays

HIGH LIMIT FAILURE alternating with

DISCONNECT POWER. If this happens, disconnect power to the fryer and call for service
immediately.

The vat stops heating and the computer displays the current temperature setting alternating with the
actual temperature (ex.

430F) until the temperature cools below 400°F (204°C).

6. Press the soft power button to cancel the alarm.

7. Once the temperature cools below 400°F (204°C) press the (2) button

once to exit the high-limit test.

8. Press the (2) button again to exit to

OFF.

9. Follow the procedures on page 4-16 to dispose of the oil.


4.13 Programming Level Two

To enter Level two programming mode:

1. With the computer OFF press the TEMP and INFO buttons simultaneously

for 10 seconds until

LEVEL 2 is displayed; a third chirp sounds.

The computer displays

ENTER Code.

2. Enter 1234.

1

2

3

4

(1234)

The computer displays

level 2 program for three seconds changing to Product

comp.