7-5

Problem

Probable Causes

Corrective Action

Frypots won’t top off.


A. Fryer temperature too low.
B. Oil is too cold.
C. JIB out of oil (yellow light illuminated)
D. Service required error exists

A. Fryer temperature must be at

setpoint.

B. Ensure that the oil in the JIB is

above 70°F (21°C).

C. Ensure the JIB is not out of oil.

Replace JIB and reset yellow LED.

If problem persists c

all your ASA

for assistance.

D

.

Call your ASA for assistance.

7.2.5 Bulk Oil System Problems

Problem

Probable Causes

Corrective Action

JIB won’t fill.


A. Incorrect setup procedure.
B. Another function is in process.
C. Dispose valve not completely closed.
D. Bulk oil tank is empty.
E. Solenoid, pump or switch issue.

A. Power cycle fryer by disconnecting

and reconnecting 5-pin control
power cord.

B. If a filtration or any other filter

menu function is in process or
FILTER NOW? YES/NO,
CONFIRM YES/NO, or SKIM VAT
are displayed, wait until the process
is complete and try again.

C. Ensure the dispose valve handle is

pushed fully closed.

D. Call your bulk oil provider.

E.

Call you ASA for assistance.

JIB or vat filling slow.

A. Pump or line issues beyond the scope of

operator troubleshooting.

A. Contact your bulk oil provider.

Frypot won’t fill.


A. Incorrect setup procedure.
B. Dispose valve not completely closed.
C. Bulk oil tank is empty.
D. RTI pump issue.

A. Power cycle fryer by disconnecting

and reconnecting 5-pin control
power cord.

B. Ensure the dispose valve handle is

pushed fully closed.

C. Call your bulk oil provider.
D. Call you ASA for assistance.

7.2.6 Error Log Codes

Code ERROR

MESSAGE

EXPLANATION

E03

ERROR TEMP PROBE FAILURE

TEMP Probe reading out of range

E04

HI 2 BAD

High limit reading is out of range.

E05

HOT HI 1

High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)

E06

HEATING FAILURE

A component has failed in the high limit circuit
such as computer, interface board, contactor or
open-high limit.

E07

ERROR MIB SOFTWARE

Internal MIB software error

E08

ERROR ATO BOARD

MIB detects ATO board connection lost; ATO
board failure

E09

ERROR PUMP NOT FILLING

Dirty pad and it needs changed or it was
bypassed; filter pump problem

E10

ERROR DRAIN VALVE NOT OPEN

Drain valve was trying to open and confirmation
is missing