Frymaster BIGLA30 User Manual

Page 17

Advertising
background image

2-8

BIGLA30 LOV™ gas fryers manufactured for Non-CE countries use different burners for each type gas. The
burners in fryers built for propane gas have a special gray-colored coating on the burner tiles to enable them to
withstand the higher caloric value of the propane gas. Burners designed for use in propane units may be used in
natural gas applications, but not vice versa.

Non-CE Gas Conversion Kits

Natural Gas to Propane (LP) Gas

Propane (LP) Gas to Natural Gas

Full Vat before 09/10: PN 826-2527

Full Vat before 09/10: PN 826-2528

Dual Vat before 09/10: PN 826-2529

Dual Vat before 09/10: PN 826-2530

Full Vat after 09/10: PN 826-2965

Full Vat after 09/10: PN 826-2967

Dual Vat after 09/10: PN 826-2966

Dual Vat after 09/10: PN 826-2968

Non-CE Gas Conversion Kits for Australia

Natural Gas to Propane (LP) Gas

Propane (LP) Gas to Natural Gas

Full Vat before 09/10: PN 826-2745

Full Vat before 09/10: PN 826-2747

Dual Vat before 09/10: PN 826-2746

Dual Vat before 09/10: PN 826-2748

Full Vat after 09/10: PN 826-2969

Full Vat after 09/10: PN 826-2971

Dual Vat after 09/10: PN 826-2970

Dual Vat after 09/10: PN 826-2972

Units manufactured for export to CE countries are equipped with “universal” burners that may be used with either
Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.

CE Gas Conversion Kits for Units with Gas Valve 810-1715

G20 or G25 (Natural) to G30 or G31 Gas:

G30 or G31 to G20 or G25 (Natural) Gas:

before 09/10 PN 826-2973

before 09/10 PN 826-2974

after 09/10 PN 826-2975

after 09/10 PN 826-2976

CE GAS CONVERSION INSTRUCTIONS


1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE Standard

Burner Manifold Gas Pressure Chart.) Do not change the orifice.

2. Between a 2

nd

family (G20 or G25) and a 3

rd

family gas (G30 Butane or G31 Propane):

a. Change the orifices.

b. Adjust the manifold pressure.

3. Remove the old rating plate and return to Frymaster. Affix the new rating plate included with the conversion

kit in place of the old rating plate stating the gas has been converted.

4. If the destination language changes, replace the rating plate. Call your local service agency or KES for a label

kit. The language of reference will be on the corner of the label.

Advertising