Frymaster BIGLA30 User Manual

Page 80

Advertising
background image

7-2

7.2

Troubleshooting Fryers

7.2.1 Computer and Heating Problems

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

No display on the

computer.

A. Computer not turned on.
B. No power to fryer.
C. Failed computer or other component

A. Press the ON/OFF switch to turn the

computer on.

B. Verify that the fryer is plugged in and

that the circuit breaker is not tripped.

C. Call your ASA for assistance.

M3000 displays

IS

VAT FULL?

YES NO after a

filtration.

A filter error has occurred due to dirty or
clogged filter pad or paper, clogged filter
pumps, improperly installed filter pan
components, worn or missing O-rings,
cold oil or filter pump thermal overload.

Follow instructions on page 5-4 through 5-
6 to clear the filter error. If problem
persists, call your ASA for assistance.

M3000 display shows

IS DRAIN CLEAR?

Drain is clogged and oil failed to drain.

Clear drain with Fryers Friend and press

9 (1) YES

button. Filtration will

resume.

M3000 displays

CHANGE FILTER

PAD?

Filter error has occurred, filter pad
clogged, 25 hour filter pad change prompt
has occurred or change filter pad was
ignored on a prior prompt.

Change the filter pad and ensure the filter
pan has been removed from the fryer for a
minimum of 30 seconds. Do NOT ignore
CHANGE FILTER PAD prompts.

Fryer does not heat.

A. Drain valve not fully closed.
B. Gas valve is not turned on.
C. Manual gas shut off valve closed.
D. Improperly connected quick-

disconnect fitting on gas line.

E. Obstructed or failed combustion air

blower.

A. Check status of MIB – Ensure

A is

displayed.

B. Turn the gas valve knob to the ON

position.

C. Verify that any in-line manual shut off

and gas main valve is open.

D. Verify that the quick-disconnect

fitting on the flexible gas line is
firmly connected to the fryer.

E. Verify that combustion air blower is

running. If not, call ASA for service.
If combustion air blower is functional,
clean and adjust per instructions in
Chapter 6 of this manual.

Fryer is operating

normally, but recovery

is slow when cooking.

Dirty or obstructed combustion air blower.

Clean and adjust per instructions in
Chapter 6 of this manual.

Fryer is operating

normally, but produces

a popping sound when

burners ignite.

A. Dirty or obstructed combustion air

blower.

B. Dirty or obstructed gas valve vent tube

(non-CE fryers only).

C. Malfunctioning combustion air blower.

A. Clean and adjust per instructions in

Chapter 6 of this manual.

B. Clean per instructions in Chapter 6 of

this manual.

C. Call your ASA.

Computer locks up.

Computer error.

Remove and restore power to the
computer. If problem persists, call your
ASA for assistance.

M3000 display shows

misconfigured

energy type

Energy type in fryer setup is incorrect.

Set proper energy type. Press 1234 to
enter setup to properly configure fryer.

Advertising