7-6

E11

ERROR DRAIN VALVE NOT CLOSED

Drain valve was trying to close and confirmation
is missing

E12

ERROR RETURN VALVE NOT OPEN

Return valve was trying to open and confirmation
is missing

E13

ERROR RETURN VALVE NOT CLOSED

Return valve was trying to close and confirmation
is missing

E14

ERROR AIF BOARD

MIB detects AIF missing; AIF board failure

E15

ERROR MIB BOARD

Cooking computer detects MIB connections lost;
MIB board failure

E16

ERROR AIF PROBE

AIF RTD reading out of range

E17

ERROR ATO PROBE

ATO RTD reading out of range

E18 Not

used

E19

M3000 CAN TX FULL

Connection between computers lost

E20

INVALID CODE LOCATION

SD card removed during update

E21

FILTER PAD PROCEDURE ERROR
(Change Filter Pad)

25 hour timer has expired or dirty filter logic has
activated

E22

OIL IN PAN ERROR

The MIB has reset the oil in pan flag.

E23

CLOGGED DRAIN (Gas)

Vat did not empty during filtration

E24

OIL LEVEL SENSOR FAILED (Gas)

Oil level sensor failed.

E25

RECOVERY FAULT

Recovery time exceeded maximum time limit.