Frymaster BIGLA30 User Manual

Page 81

Advertising
background image

7-3

7.2.2 Error Messages and Display Problems

Problem

Probable Causes

Corrective Action

M3000 display shows

hot-hi-1.

Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF (202ºC).

Shut the fryer down immediately and
call your ASA for assistance.

M3000 display shows

REMOVE

DISCARD.

A product cook is started that has a different
setpoint than the current vat temperature.

Remove and discard product. Press the
cook button under the display with the
error to remove the error. Reset the
setpoint of the vat before trying to cook
product.

M3000 display shows

RECOVERY

FAULT and alarm

sounds.

Recovery time exceeded maximum time
limit.

Clear error and silence the alarm by
pressing the 9 button. Maximum
recovery time for gas is 2:25. If the error
continues call your ASA for assistance.

M3000 display is in
wrong temperature

scale (Fahrenheit or

Celsius).

Incorrect display option programmed.

Toggle between F° to C° by pressing
and holding

3and4simultaneously

until

TECH MODE appears. Enter

1658. The computer displays OFF.
Turn the computer on to check
temperature. If the desired scale is not
displayed, repeat.

M3000 display shows

hELP HI-2 or

High limit

failure.

Failed high limit

Shut the fryer down immediately and
call your ASA for assistance.

M3000 display shows

TEMP PROBE

FAILURE.

Problem with the temperature measuring
circuitry including the probe or damaged
computer wiring harness or connector.

Shut the fryer down and call your ASA
for assistance.

M3000 display shows

HEATING

FAILURE.

Gas valve off, failed computer, failed
transformer, open high-limit thermostat.

It is normal for this message to appear
during startup if the lines have air in
them. Check that the gas valve is on. If
it continues, shut the fryer down and
call your ASA for assistance.

M3000 displays

SERVICE

REQUIRED

followed by an error

message.

An error has occurred which requires a
service technician.

Press 8 (2 NO) to continue cooking and
call your ASA for assistance. In some
cases, cooking may not be allowed.

7.2.3 Filtration

Problems

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Fryer filters after each

cook cycle.

Filter after setting incorrect.

Change or overwrite the filter after setting
by re-entering the filter after value in level
two. See section 4.13.5 on page 4-33.

MAINT FILTER

(Manual Filter) won’t

start.

Temperature too low.

Ensure fryer is at setpoint before starting
MAINT FILTER.

M3000 display shows

filter busy.

A. Another filtration cycle or filter pad

change is still in process.

B. MIB has not cleared checking system.

A. Wait until the previous filtration

cycle ends to start another filtration
cycle. Change filter pad if prompted.

B. Wait one minute and try again.

Advertising