5-6

5.4.3 Filter Error Flowchart

Change filter pad and

ensure filter pan is

pulled out for a

minimum of 30

seconds.

Fryer returns to

cook mode for 4

minutes or 15

minutes if pad

change expired.

NORMAL

OPERATION

RESUMES

SIXTH

CONSECUTIVE

FILTER ERROR

Fryer returns to

cook mode for 15

minutes.

TECH

ENTERS

CODE

MESSAGE

DISPLAYED

Call an Authorized

Repair Technician


This chart follows the process of clearing
a filtration issue. The prompt is
displayed when any of the following
occur:

1. a clogged filter pad,
2. a tripped or defective filter pump,
3. a leaky O-ring on the pick-up tube,
4. a failed drain valve/actuator, or
5. a failed return valve/actuator.

If the computer displays

SERVICE

REQUIRED, the fryer can be used in
most cases by answering

NO when the

prompt for

SYSTEM ERROR

FIXED? YES NO is displayed. The
message repeats every 15 minutes until
the issue is repaired and fryer reset by a
technician.