2-4

NOTE: There are no built-in leveling devices on fryers equipped with casters. The floor where the fryer is to
be installed must be level.

3. Test the fryer electrical system:

a. Plug the fryer electrical cord(s) into a grounded electrical receptacle. NOTE: To ensure the safe and

efficient operation of the fryer and hood, the electrical plug for the 120-volt line, which powers the
hood, must be fully engaged and locked in its pin and sleeve socket.

b. Place the power switch in the ON position.

• For fryers having computers, verify that the display indicates ON.

• If the store is equipped with a hood interlock system, the hood exhaust fan should be on. If not, the

store hood interlock system is improperly wired and must be corrected.

c. Place the fryer power switch in the OFF position. Verify that the display indicates

OFF. The hood

exhaust system should be off when all computers display OFF.


4. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is configured for the

proper type of gas before connecting the fryer quick-disconnect device or piping from the gas supply line.


5. Verify the minimum and maximum gas supply pressures for the type of gas to be used in accordance with the

accompanying tables and the data plate on the inside of the fryer door.

Orifice Diameter

Single

Vat

Dual

Vat

Single

Vat

Dual

Vat

G20

20

2 x 3.40 2 x 3.40

7 mbar

7 mbar

G25

20 or 25

2 x 3.40 2 x 3.40

10 mbar

10 mbar

G30

28/30 or 50

2 x 2.05 2 x 2.05

17 mbar

17 mbar

G31

37 or 50

2 x 2.05 2 x 2.05

20 mbar

20 mbar

CE Standard

for Incoming Gas Pressures

for Fryers Manufactured After April 1999

(1) mbar = 10,2 mm H

2

O

Gas

Pressure

(mbar)

(1)

Regulator Pressure

Non-CE Standard

for Incoming Gas Pressures

Gas

Minimum

Maximum

Natural

6" W.C.

1.49 kPa

14.93 mbar

14" W.C.
3.48 kPa

34.84 mbar

LP

11" W.C.
2.74 kPa

27.37 mbar

14" W.C.
3.48 kPa

34.84 mbar

6. For fryers equipped with a FootPrint Pro system (BIGLA30 models) plug the electrical cord(s) into a power

receptacle behind the fryer.

2.4

Connection to Gas Line

DANGER

Before connecting new pipe to this appliance, the pipe must be blown out thorough-
ly to remove all foreign material. Foreign material in the burner and gas controls will
cause improper and dangerous operation.

DANGER

The appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of the system at test pressures in
excess of ½ PSI (3.45 kPa, 13.84 inches W.C.) to avoid damage to the fryer’s gas
tubes and gas valve(s).