63
Basic software procedures
Ê
Press the On / Off button to start up the server.
The system will detect the USB stick and the BIOS recovery process will be
performed.
V
CAUTION!
Do not interrupt the BIOS upgrade process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê
After completion of the flash process, shut down the server.
Ê
Open the side cover as described in section
.
Ê
Disable BIOS recovery mode using the onboard jumpers:
I
For detailed information on jumper settings, refer to section
Ê
Close the side cover as described in section
.
5.2.2
Updating RAID controller firmware
The onboard RAID controller firmware is updated with the system board BIOS.
Please proceed as described in section
"Updating the system board BIOS" on
.