RIS

Reset to Initial State: Resets the value or state of several operating
features. This sequence resets the printer to a set of operating values

and conditions similar to the factory default settings (see table
below).
General Command Syntax
ESC c

Decimal:

27 75

Hex

:

1B 63

BASIC:

CHR$(27);”c”;

Selectable Parameter

Reset Condition

Printing Status

On-line

Horizontal Pitch

10 characters per inch

Vertical Pitch

6 lines per inch

Font

Data Processing

Forms Length

66 lines (11 inches)

Active position

Column 1 on the current line

Top Margin

Line 1

Bottom Margin

Line 66

Left Margin

Column 1

Right Margin

Column 136

Underlining

Disabled

Bolding

Disabled

Italics

Disabled

Double Underline

Disabled

Overline

Disabled

Expansion

No character expansion

GL Character Set

US ASCII

GR Character Set

Digital Supplemental

G0

US ASCII

G1

VT100 Graphic Character Set

G2

Digital Supplemental

G3

US ASCII

Autowrap

Disabled

Line Feed/New Line
Mode

Reset

Horizontal Tabs

Every 8 columns (9,17 …)

Unsolicited Reports

Disabled

Super/Subscripts

Disabled

Carriage Return/New

line

Reset

Vertical Tabs

Every line (1-66)

NOTE

This sequence and the DECSTR reset sequence have the same

function.