Genicom GEK 00031B User Manual

Page 233

Advertising
background image

GEK-00029B

5000 Series Programmer’s Manual

233

HPA

Horizontal Position Absolute: Moves to a new active horizontal
position. Motion occurs either to the right or to the left.
Source: Application

Destination: Levels 2, 3

Format

CSI Pn 9/11 - 6/0
Description

Select Pn as follows:

Pn

Meaning

0

Interpreted as 1

n

Number of units, depending on Positioning

Unit Mode (PUM) and Select Size Unit (SSU).

When lining attributes are invoked by Select Graphic Rendition
(SGR), HPA underlines, double underlines, overlines, or strikes
through from the current position to the target position.

The First Character Flag has no effect on HPA.
Error Handling

If Pn is to the left of the Left Margin Position, the printer sets the

horizontal position to the Left Margin Position.

Sets the right margin flag if the Pn is greater than the right margin.

Clears the right margin flag if the Pn is less than or equal to the right
margin.

Advertising