Evfu default, Skip to channel command – Genicom GEK 00031B User Manual

Page 44

Advertising
background image

Chapter 2. ANSI Emulation

GEK-00029B

44

EVFU Default

The default EVFU will be generated based on the current form length
and lpi setting under the following conditions:

When the printer is initialized

When either the forms definition or lpi setting is changed

When the start EVFU load escape sequence ESC ] is immediately
followed by the end load sequence ESC \

When the emulation is changed from P Series or Dataproducts, to
ANSI

The following chart shows how the default EVFU table is defined:

CHANNEL

DESCRIPTION

1

Top Margin (first line

2

Bottom Margin (last line)

3

Single Spacing

4

Double Spacing

5

Triple Spacing

6

Half Form

7

Quarter Form

8

Tenth Line

9

Bottom of Form (bottom margin)

10

Bottom of Form minus 1 line

11

Top of Form minus 1 line (last line this form)

12

Top of Form

Skip to Channel Command

ESC [ p1 ; p2 ! p

GENVFU (VFU Channel Command): Commands vertical paper
movement to the channel specified by the number formed by p1 and
p2. Valid channel numbers are in the range 1- 12.

0;1 - selects channel 1
0;9 - selects channel 9

1;1 - selects channel 11

Channel 1 is always used for TOF; channel 12 is always used for
vertical tab. When the channel number is greater than 12, the
program defaults to channel 1. If the table has not been loaded and a
channel command is received, it is ignored.

Decimal:

27 91 <p1> ; <p2> ! 112

Hex:

1B 5B <p1> 3B <p2> 21 70

BASIC:

CHR$(27);"[<p1>;<p2>!p";