Contact reverse test, Up/down force erase - open/close travel limit – Genie BeltLift 1022 User Manual

Page 22

Advertising
background image

PN# 36420Supplement, 10/27/2008

22

FIG. 6-6

2 x 4 under center of door opening.

CONTACT REVERSE TEST

The force adjustments and limit switch settings
MUST BE COMPLETED before testing.

1. Testing.

• Open garage door using Wall Button.

– Place a 2" x 4" board (laid flat) under center

of garage door opening (Fig. 6-6).

• Close door using Wall Button.
• When door contacts board, it must stop and

reverse (within 2 seconds) to open position.

2. Adjustment.

• If the door does not properly reverse.

– Check to see if door has "close" limit

programmed. It should not have reached its
"close" limit before hitting board.

– If the door STOPS but does not reverse,

decrease "CLOSE FORCE" control
setting slightly (turn it counter-clockwise).

• Test again. Repeat as necessary until door

reverses upon contacting board.

CLOSE

1. Press and hold both of the "SET" buttons

( & ) together until the green indicator
light blinks (about 5 seconds).

2. All close and open travel limit settings are

erased. Then follow the steps above to
reprogram close and open travel limits.

NOTE: The opener will not close the door
automatically unless the Safe-T-Beam

®

System is

installed.

SET

SET

1. By turning the Down Force Control

clockwise,

the DOWN force can be increased. By turning
the Down Force Control

counter-clockwise,

the DOWN force can be decreased. Set the
DOWN force level at the minimum force required
to close door without reversing.

2. Once the desired level is selected, this stores the

maximum force level for the DOWN direction in memory.

3. By turning the Up Force Control

clockwise, the

UP force can be increased. By turning the Up Force
Control

counter-clockwise, the UP force can be

decreased. Set the UP force level at the minimum
force required to open door without stopping.

4. Once the desired level is selected, this stores

the maximum force level for the UP direction
in memory.

OPEN

CLOSE

OPEN

CLOSE

UP/DOWN FORCE

ERASE - OPEN/CLOSE TRAVEL LIMIT

OPEN

FORCE

CLOSE

Down Force

Control

Adjustment

Up Force

Control

Adjustment

ROTATE

CLOCKWISE

ROTATE

COUNTER-CLOCKWISE

FIG. 6-5

Force Control Adjustment.

Advertising