Troubleshooting 4-37

NovaJet 800 Series Service Manual

Figure 4-34. Defective Carriage PWA (Color Test).

15. Inspect and clean stepper motor and lower roller drive gears if

printer is older than 5 years. (Every two years if printer is used
for textile printing.) Other unique microbanding causes include
synchronization errors from the stepper drive system due to
defects or gear cleanliness.

Figure 4-35. Defective Stepper Motor.

16. Replace stepper motor for consistently spaced horizontal

patterns (2 - 10 mm apart) when printer is run in the enhanced
modes with a test print. Often a lower roller drive noise will
accompany the banding. Inspect stepper motor gearing/lower
roller for damage/debris (ensure screws are tight). Check
stepper motor winding resistance (7.2-8.0 ohms; check full
360-degree rotation)