Troubleshooting 4-79

NovaJet 800 Series Service Manual

Media Sensor Reference Points Not Initialized

Hardware Failures/Diagnostic Tests

Quick Troubleshooting List

1.

Send a test image (PRT or RTL) directly to printer to verify a
hardware failure.

2.

If the carriage stops during normal travel clean encoder strip/slide
shaft/bushing/belt; reseat trailing cable connections if necessary.

3.

Check feed/take-up modes and operation. Run a legs test under
Diagnostics.

4.

Reseat all printer cable connections.

5.

Refresh the printer firmware.

Figure 4-81. Main PWA LED Operation.

6.

Check Main PCB LED’s (light emitting diodes):

D1 – Normally flashes; DSP is not active. Steady during print operations.
D9 – Normally flashes; Power PC processor is idle. Stops flashing when
processor is
active (i.e. during paper sensing operations).
D10 – Normally OFF; Flashes during initialization, then turns off. LED
staying on would indicate a problem when the FPGA is unconfigured.
Ensures the gate array chips have been properly programmed (one on
Main PWA and on each Carriage PWA).
D8 - +24V available.