Maintenance
3-11
NovaJet 800 Series Service Manual
MAINTENANCE
J 7
J 6
J 4
J 5
J 3
J 2
J 1
Figure 3-5. Carriage PWA Connection Locations.
Table 3-2. Carriage PWA Connections.
J1
Trailing Cable
J5
Cyan/Slot 2 Drivers
J2
Paper Sensor
J6
Magenta/Slot 3 Drivers
J3
Encoder Sensor
J7
Yellow/Slot 4 Drivers
J4
Black/Slot 1 Drivers
Figures 3-4 and 3-5 show the locations of all the connectors on the
Main PWA and carriage boards respectively. The J2 and J3 jack
connections shown on Figure 3-5 are used on the right carriage assem-
bly only.
To remove the ribbon cables from their connectors, lift the connector’s
ribbon locking mechanism as shown in Figure 3-6. To reattach, depress
the locking mechanism back into the locking position after inserting the
ribbon cable end.