Db25 female on flying lead – Perle Systems RIO 5500036-17 User Manual

Page 185

Advertising
background image

RIO Remote I/O System User Guide
Installing a Long Distance Module (LDM)

Page 185

Chapter 2 Installing hardware and software

DB25 female on flying lead

Pin

Signal

Name

Direction

1

Chassis

Chassis Ground

2

TXD

Transmit Data

Output RS232

3

RXD

Receive Data

Input RS232

4

RTS*

Request To Send

Output RS232

5

CTS*

Clear To send

Input RS232

6

N/C

Not Connected

7

GND

Ground

8

DCD*

Data Carrier Detect

Input RS232

9

DCD+

Data Carrier Detect

Input RS422

10

RXD-

Inverse RXD

Input RS422

11

RXD+

Receive Data

Input RS422

12

TXD-

Inverse TXD

Output RS422

13

TXD+

Transmit Data

Output RS422

14

CTS-

Inverse CTS

Input RS422

15

TXC

Transmit Clock

Input RS232

16

CTS+

Clear To Send

Input RS422

17

RXC

Receive Clock

Input RS232

18

RTS-

Inverse RTS

Output RS422

19

RTS+

Request To Send

Output RS422

20

DTR*

Data Terminal ready

Output RS232

21

DCD-

Inverse DCD

Input RS422

22

DTR+

Data Terminal Ready

Output RS422

23

DTR-

Inverse DTR

Output RS422

24

RXC-

Inverse RXC

Input RS422

25

RXC+

Receive Clock

Input RS422

Advertising