Chapter 3 RIO Cabling information
Link cable specification
RIO link cables should conform to the following specification:
Item
Specification
Size
7/0.2 minimum
Type
Two individually screened twisted pairs with drain and overall screen,
sheathed over all in grey PVC (or PTFE). The screen is aluminised
polyester tape. The drain wire is tinned. For particularly noisy
environments and distances greater than 5 metres we recommend an
additional overall braid screen
Length
5.0 metres maximum
Noise
The receiver does not require a differential input voltage more than 200mV to
correctly assume the binary state over an entire common-mode voltage range
of -7V to +7V. Thus, noise must not reach more than +/-7V.
Nominal Impedance
100 Ohms
Ground Potential
The maximum voltage between either receiver input and receive ground
must not exceed 8V (80% - 3V signal + 7V common mode voltage) in
magnitude. Thus excessive differences in 0V between communication
devices (systems) are unacceptable. Typical causes are insufficient
mains earthing, heavily laden mains, or heavily laden PC slots