Remote terminal adaptors (rtas) – Perle Systems RIO 5500036-17 User Manual

Page 277

Advertising
background image

RIO Remote I/O System User Guide
Solaris troubleshooting

Page 277

Remote Terminal Adaptors (RTAs)

Problem

Action required

RTA not recognised by system

1. Check physical connections and power.

See

page 161

.

2. Run the

rioconfig

utility to update RIO

system settings.
See

page 51

.

RTA not booted by system

1. Check the

rio.cf

file to make sure the RTA

entry exists and contains the

boot

field.

See

page 164

.

2. Delete the

rio.cf

file and run the

rioconfig

utility to recreate the system settings.
See

page 164

and

page 51

.

RTA8 LED next to port 5 does not light up

The host card has already assigned 128 ports, if you
haven’t got 128 ports installed, this means that you
have previously removed one or more RTAs from the
network but not deleted them from the configuration.

RTA16 con LED does not light up

You have already installed the maximum number of
RTAs up to 128 ports. This situation may arise if you
have previously removed RTAs from the system but
forgotten to delete them from the configuration using
the rioconfig utility.