Printronix ThermaLine Series User Manual

Page 196

Advertising
background image

Bar Codes

5–58

Quiet Zone

Both ends of the bar code structure have blank quiet zones. The quiet zones

must be at least 0.25 inches wide and completely blank to ensure accurate

reading of the start/stop codes and to prevent adjacent bar codes from

overlapping. The IGP/PGL automatically produces the left quiet zone; be

sure to provide sufficient space on the form for the right quiet zone.

Start/Center/Stop Codes

The start/center/stop codes are special character codes marking those

portions of the bar code. These codes are automatically provided.

Data Field

The bar code symbol uses a series of varying width bars and spaces to

represent a limited character set (numbers 0–9 and Special Characters Start,

Center, and Stop). The bars and spaces vary in width from one to four

modules. Each character consists of two bars and two spaces that total

seven modules. The symbol coding of the left data field is different from

the right data field to permit read direction sensing.

The optional 2– or 5–digit add–on data, placed within the delimiter at the

end of the bar code, typically identifies a periodical issue number or price,

respectively.

Readable Data

The human readable data field provides a readable interpretation of the bar

code data. It can either be suppressed or printed below the bar code symbol.

Check Digit

The modulo–10 check digit is automatically calculated and inserted in the

bar code symbol. The check digit verifies accurate scanning.