Bar Codes

5–102

e.

Replace L with a number equaling the total

number of characters in the field. (The actual

data provided dynamically during the Execute

Form Mode can be less than L.)

f.

The information for the data field is entered

dynamically during the Execute Form Mode.

(Refer to “Execute Form: Dynamic Bar Code

Data” on page 4–55 in the “Commands”

chapter.) Do not use the data field parameter to

enter data when the BFn parameters are used.

However, refer to the data field description for

available characters.

DARK

Optional parameter to produce darker looking bar

codes. Enter DARK. Refer to “Dark Printing” on page

4–10 for more information.

SR

Defines the starting row for the bar code. Enter a value

within the range of the 4–inch vertical address block.

Character row or dot row is specified based on the

Scale command (page 4–88), or use the CP.DP format

(page 4–7).

SC

Defines the starting column of the bar code. Enter a

value between the 1/2–inch left and right margins of

the mailpiece. Character column or dot column is

specified based on the Scale command (page 4–88), or

use the CP.DP format (page 4–7).

D

The printable character (delimiter) identifying the start

and finish of the data field. Enter any printable

character other than a slash (/) the SFCC, or a character

used within the data. The same character must be used

at both ends of the data field but it will not print with

the data.

data field

The bar code data. Enter 5 digits (for zip code), 9 digits

for a nine–digit zip code, or 11 digits (for the

Advanced Bar Code format). The available characters

for the data field are 0 through 9 (30 through 39 hex,

respectively).